<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Laboratory Gas Equipment &#8211; arigmed</title>
	<atom:link href="https://arigmed.com/product-category/laboratory-gas-equipment/feed/" rel="self" type="application/rss+xml" />
	<link>https://arigmed.com</link>
	<description>Medical Gases Equipment Manufacturer</description>
	<lastBuildDate>Mon, 21 Apr 2025 20:17:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://arigmed.com/wp-content/uploads/2019/07/cropped-favicon-32x32.png</url>
	<title>Laboratory Gas Equipment &#8211; arigmed</title>
	<link>https://arigmed.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">246496849</site>	<item>
		<title>Laboratoty Rotary vane Lubricated Vacuum Pump</title>
		<link>https://arigmed.com/tienda/laboratory-gas-equipment/laboratoty-rotary-vane-lubricated-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 30 Nov 2023 20:33:00 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=14332</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-116428 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-813043 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-970249 kc_text_block">
<p><strong>Laboratory Rotary vane Vacuum Pumps.</strong></p>
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/mils-logo-pequeno.png" alt="" width="85" height="52" />Vacuum Pumps:</strong></p>
<ul>
<li>MILS Brand Vacuum Pumps made in France <em><strong>Oil Lubricated Rotary Vane Technology</strong></em> (1.5 HP until 20 HP), EVISA Model with a 220v 60htz multi voltage direct drive electric motor, (other voltages must be notified in advance to the factory).</li>
<li>Certifications: C E</li>
</ul>
<p><strong>Vacuum Tank:</strong></p>
<ul>
<li>ASME standard Vacuum tank manufactured.</li>
<li>ASME stamped by the vacuum tank manufacturer.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electric Control Panel NEMA12 class cabinet to coordinate alternation sequences, simultaneous use and stop of vacuum pumps, as well, NFPA99 type alarms and local signals.</li>
<li>Hour counter by each vacuum pump.</li>
<li>Level vacuum  gauge elctronic type.</li>
</ul>
<p><strong>Filters:</strong></p>
<ul>
<li>Particle Filter (paper cartridge) to protect each vacuum pump.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Laboratory.</strong></li>
</ul>
<div><img decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<div style="text-align: center;"><strong>Warning</strong></div>
<p style="text-align: center;">To quote, user must be provide vacuum delivery in SFCM (Standart Cubic Feet per Minute) and geographical location with height according to the sea level. Not suitable for evacuation of halogenated gases and indoor Use Only. <strong style="color: #ff0000;">Factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance. </strong></p>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">14332</post-id>	</item>
		<item>
		<title>Laboratory Automatic Manifold</title>
		<link>https://arigmed.com/tienda/laboratory-gas-equipment/laboratory-automatic-manifold/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Tue, 15 Aug 2023 22:35:15 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=13824</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-609496 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-863994 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-162196 kc_text_block">
<p style="text-align: justify;"><strong>Automatic cylinder center for laboratory use (Manifold), for automatic exchange of benches, complies with ASTM B819 (clean for use with oxygen). The parts that make up the construction of our cylinder manifolds are specifically or custom-made, we do not use commercial parts and connectors.</strong></p>
<p><strong>Cabinet:</strong></p>
<ul>
<li>Indoor</li>
</ul>
<p><strong>Control system:</strong></p>
<ul>
<li>Operated by a high speed electronic PCB system with 7&#8243; LCD color display, touch screen control.</li>
<li>Electric valve 110-220 vac normally open.</li>
<li>Check valves</li>
<li>4-20Map high and low pressure transducers</li>
</ul>
<p><strong>Graphics:</strong></p>
<ul>
<li>Display of high and low pressure readings for the primary and secondary cylinder banks in real time.</li>
<li>Display of high and low pressure readings for the output supply line in real time.</li>
<li>pressure units.</li>
<li>Alarm signals.</li>
</ul>
<p><strong>Signals (Alarms):</strong></p>
<ul>
<li>Low delivery pressure alarm.</li>
<li>Alarm header empty.</li>
<li>Reserve alarm in use.</li>
<li>High pressure alarm (when it is above 20% of the nominal pressure).</li>
<li>Leakage alarm (when a pressure drop of 25% is detected in the bench designated as reserve or standby).</li>
</ul>
<p><strong>Derivation System (By Pass):</strong></p>
<ul>
<li>System of 2 final line regulators for low pressure with manual isolation of ball valves made of stainless steel (one in use and the other in reserve).</li>
<li>Overpressure and vent valve system:</li>
<li>Protection system interconnected with a circuit of relief valves and facing outside the cabinet of the supply center (manifold).</li>
</ul>
<p><strong>Emergency Ports:</strong></p>
<ul>
<li>Located after end line regulators and for low pressure only.</li>
<li>Coupling with DISS CGA V-5 input.</li>
</ul>
<p><strong>Pressure gauges:</strong></p>
<ul>
<li>Analog type for high and low pressure stages.</li>
</ul>
<p><strong>Comunication system:</strong></p>
<ul>
<li>Relay connections (dry contact) for monitoring each alarm for remote connection with master alarm panels, as well as the integration of a remote management and surveillance system BMS (Building Management System) common language based on relay switching.</li>
<li>Two-wire Modbus RTU RS485 communication connection in slave mode for monitoring pressures in PSI and alarm states from a BMS (Building Management System), SCADA (Supervisory Control and Data Acquisition) system or any equipment configured as master.</li>
<li>Button for choosing the main header of use</li>
</ul>
<div><img decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<div style="text-align: center;"><strong>Warning:</strong></div>
<p style="text-align: center;">Do not use oil and its derivatives, operation and maintenance personnel must be certified for the safe operation of the equipment. Quality and Purity Degree of the Gases as well as the state of the containers and their connections will always be the responsibility of their supplier.</p>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13824</post-id>	</item>
		<item>
		<title>Screw type Oilfree Air Compressor Water Lubricated</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-screw-air-compressor-water-lubricated-eng_us/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Wed, 23 Jun 2021 17:00:19 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=8772</guid>

					<description><![CDATA[<img class="wp-image-9640 alignleft" src="https://arigmed.com/wp-content/uploads/2021/06/MADE-IN-TAIWAN-2021-300x189.png" alt="" width="140" height="88" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">@media only screen and (min-width: 1000px) and (max-width: 5000px){body.kc-css-system .kc-css-799655{width: 100%;}}</style>
<section class="kc-elm kc-css-276322 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-799655 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-883594 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Oilfree Screw Air Compressor Water Lubricated,  designed for continuous heavy duty.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/denair-logo.png" alt="" width="114" height="30" />Screw Compressors:</strong></p>
<ul>
<li>Oil-free and water-lubricated Screw System for <strong>152 psig continuous working pressure</strong>, DENAIR brand of Taiwan and stainless steel screw compressor Made in Germany, to an optimal isothermal compression and 100% oil-free air delivery.</li>
<li>Stainless Steel Filters and pipes made, to prevent materials corrosion.</li>
<li>Belt Driven Transmission, standard electric motor 220v 60htz, (other voltages must be specified in advance to the factory).</li>
<li>DENAIR Brand.</li>
<li>Compressor Certification: ISO 8573-1:2010.</li>
</ul>
<p><strong>Cabinet:</strong></p>
<ul>
<li>Silent type cabinet.</li>
</ul>
<p><strong>Air Storage Tank:</strong></p>
<ul>
<li>Air and water Storage Container stainless steel made.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electronic control panel to coordinate stop and compressor functions.</li>
<li>LCD touch screen control and display, to compressor operation status.</li>
</ul>
<p><strong>Designed for:</strong></p>
<ul>
<li>Pharmaceutical,  Laboratories and equipement test facilities.</li>
<li>Hyperbaric Chambers.</li>
<li><strong>Medical, for Oxygen and Air Production (only in addition to other systems and devices).</strong></li>
<li>Industrial (Where Oil Free Air is required).</li>
<li>Food (Where Oil Free Air is required).</li>
</ul>
<p><strong>Compliance Regulations when it´s Configured to Produce Medical Air:</strong></p>
<ul>
<li>NFPA99, only in addition to other systems and equipment for air regulation and purification</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>OilFree Air Class 0 Arigmed´s System Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="113" height="45" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in CFM (cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in CFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">Factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">8772</post-id>	</item>
		<item>
		<title>Non Corrosive Gas Semiautomatic Manifold</title>
		<link>https://arigmed.com/tienda/laboratory-gas-equipment/non-corrosive-gas-semiautomatic-manifold-en_us/</link>
		
		<dc:creator><![CDATA[Clara Quezada]]></dc:creator>
		<pubDate>Thu, 03 Oct 2019 15:21:24 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=4095</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-378928 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-12368 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-895625 kc_text_block">
<p style="text-align: justify;"><strong>Non corrosive gases semiautomatic Manifold to laboratory applications, first cylinder header change in automatic mode by pressure difference, subsequent header changes in manual mode, all switchover cicles designation by main supply cylinder header selector lever, complies with NFPA99 and ASTM B819 (clean for oxygen use). The parts that make up the construction of our cylinder manifolds are specifically or custom-made, we do not use commercial parts and connectors.</strong></p>
<p><strong>Mounting Plate:</strong></p>
<ul>
<li>In door use only</li>
<li>Carbon steel sheet 18 gauge made, powder coating finish.</li>
<li>Availabel in stainless steel sheet 18 gauge (upon request).</li>
</ul>
<p><strong>Control System:</strong></p>
<ul>
<li>PCB electronic system with high bright LEDs visual indicators for manifold operating modes.</li>
<li>Backflow valves (checks) between cylinder headers to pressure diffrerential control.</li>
<li>High pressure 4-20Map transducers to primary and secondary cylinder headers.</li>
</ul>
<p><strong>Visual Signals:</strong></p>
<ul>
<li>USE-READY-EMPTY condition with high bright LEDs visual indicators for each cylinder header (primary and secondary).</li>
</ul>
<p><strong>Bypass System:</strong></p>
<ul>
<li>2 Low pressure final line regulators with stainless steel ball valves manual isolation (one regulator in use and the other in backup).</li>
</ul>
<p><strong>Overpressure and Vent Valve:</strong></p>
<ul>
<li>Low pressure stage relief valve located before manifold outlet to protect the main pipe medical gas source.</li>
</ul>
<p><strong>Communications:</strong></p>
<ul>
<li>1 Output port relay type connection to medical gas master panel, notify cylinders headers switchover.</li>
</ul>
<p><strong>Emergency Port:</strong></p>
<ul>
<li>Located in the low pressure stage before the outlet of manifold.</li>
<li>DISS DEMAND CGA V-5 inlet coupling port, according to the medical gas manifolds.</li>
</ul>
<p><strong>Pressure Gauges:</strong></p>
<ul>
<li>High and low pressure analog type.</li>
</ul>
<div> </div>
<div style="text-align: center;"><strong><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" />Warning:</strong></div>
<p style="text-align: center;">Do not use oil and its derivatives, operation and maintenance personnel must be certified for the manifold safe operation. Quality and Medical Gases Purity Degree, as well condition of containers, cylinders and their connections will be always responsibility of the medical gases supplier.</p>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4095</post-id>	</item>
		<item>
		<title>Corrosive Gas Semiautomatic Manifold</title>
		<link>https://arigmed.com/tienda/laboratory-gas-equipment/corrosive-gas-semiautomatic-manifold-en_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 08 Jul 2019 15:21:20 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/manifold-semiautomatico-para-gases-corrosivos/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-998393 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-460178 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-274892 kc_text_block">
<p style="text-align: justify;"><strong>Corrosive Gas Manifold to laboratory applications, first cylinder header change in automatic mode by pressure difference, subsequent header changes in manual mode, all switchover cicles designation by main supply cylinder header selector lever. The parts that make up the construction of our cylinder manifolds are specifically or custom-made, we do not use commercial parts and connectors.</strong></p>
<p><strong>Mounting Plate:</strong></p>
<ul>
<li>In door use only</li>
<li>Carbon steel sheet 18 gauge made, powder coating finish.</li>
<li>Availabel in stainless steel sheet 18 gauge (upon request).</li>
</ul>
<p><strong>Control System:</strong></p>
<ul>
<li>Flash arrestors and backflow valves (checks) to pressure diffrerential control.</li>
</ul>
<p><strong>Pressure Gauges:</strong></p>
<ul>
<li>High and low pressure analog type.</li>
</ul>
<div></div>
<div style="text-align: center;"><strong><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" />Warning:</strong></div>
<p style="text-align: center;">Do not use oil and its derivatives, operation and maintenance personnel must be certified for the manifold safe operation. Quality and Medical Gases Purity Degree, as well condition of containers, cylinders and their connections will be always responsibility of the medical gases supplier.</p>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6030</post-id>	</item>
		<item>
		<title>Low Pressure Laboratory Gases User´s Connection Point to NON-CORROSIVE gases</title>
		<link>https://arigmed.com/tienda/laboratory-gas-equipment/low-pressure-laboratory-gases-users-connection-point-to-non-corrosive-gases-en_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 08 Jul 2019 15:17:29 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/punto-de-uso-para-gas-de-laboratorio/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-549640 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-105860 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-84776 kc_text_block">
<p>
<strong>Low Pressure Laboratory Gases User´s Connection Point to NON-CORROSIVE gases.</strong></p>
<p><strong>Manufacturing Materials:</strong></p>
<ul>
<li>Connection Blocks: Brass Nickel finish made,10mm straight threaded inlet connection and 1/4 &#8220;NPT threaded outlet, hose nipple option.</li>
<li>Flow Opening Valve: Single-body ball-type stainless steel made with PTEF seals, 1/4 turn with butterfly handle.</li>
<li>Pressure Gauges: 1 1/2 ”dial back connection, sight glass and stainless steel case.</li>
<li>Regulator: High flow and low pressure regulator made in France.</li>
</ul>
<p><strong>Optional:</strong></p>
<ul>
<li>Flowmeter 0-15 L.P.M. for non-corrosive gases, 50-55 PSI maximum input pressure.</li>
</ul>
<p><strong>Mounting Plate:</strong></p>
<ul>
<li>Stainless steel sheet gauge18.</li>
</ul>
</div>