<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Medical Air and Vacuum Systems &#8211; arigmed</title>
	<atom:link href="https://arigmed.com/product-category/medical-air-and-vacuum-systems/feed/" rel="self" type="application/rss+xml" />
	<link>https://arigmed.com</link>
	<description>Medical Gases Equipment Manufacturer</description>
	<lastBuildDate>Tue, 24 Feb 2026 18:11:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://arigmed.com/wp-content/uploads/2019/07/cropped-favicon-32x32.png</url>
	<title>Medical Air and Vacuum Systems &#8211; arigmed</title>
	<link>https://arigmed.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">246496849</site>	<item>
		<title>Oil Free Piston Air Compressor V.1</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-piston-air-compressor-v-1/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Tue, 24 Feb 2026 17:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16479</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-781829 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-709137 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-999084 kc_text_block">
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="122" height="47" /></strong></p>
<section class="kc-elm kc-css-507874 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-645604 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-819843 kc-animated kc-animate-eff-fadeInRight kc_text_block">
<p><strong>Oil-free reciprocating (piston) compressor, one stage, V.1 model.</strong></p>
<ul>
<li>Brand <em><strong>ARIGMED.</strong></em></li>
<li>100% manufactured in <em><strong>MEXICO.</strong></em></li>
<li>Spare parts and components are compatible exclusively with ARIGMED brand equipment; the unit is intended for indoor use only.</li>
<li><strong style="color: #ff0000;">The factory is NOT responsible for equipment failure resulting from lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16479</post-id>	</item>
		<item>
		<title>Oil Free Piston Air Compressor</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-piston-air-compressor/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Sat, 02 Aug 2025 23:44:11 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16367</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-507874 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-645604 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-819843 kc-animated kc-animate-eff-fadeInRight kc_text_block">
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="122" height="47" />Oil-free reciprocating (piston) compressor, available in one and two stages.</strong></p>
<ul>
<li>Brand <em><strong>ARIGMED.</strong></em></li>
<li>100% manufactured in <em><strong>MEXICO.</strong></em></li>
<li>Spare parts and components are compatible exclusively with ARIGMED brand equipment; the unit is intended for indoor use only.</li>
<li><strong style="color: #ff0000;">The factory is NOT responsible for equipment failure resulting from lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16367</post-id>	</item>
		<item>
		<title>Medical Air Reciprocant Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/medical-air-reciprocant-compressor-system/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Sat, 02 Aug 2025 22:46:13 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16362</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-755586 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-654956 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-803598 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>Packaged system for reciprocating medical air production, Arigmed </strong></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li><em><strong>Certified under ISO 8573-1:2010 Class 0</strong></em>.</li>
<li>Complies with NFPA99.</li>
<li>To quote the equipment, the medical air consumption in SCFM (standard cubic feet per minute) is required, based on the requirements specified by the NFPA99 code.</li>
<li>Refer to the free air delivery capacity table in SCFM in the equipment&#8217;s technical datasheet.</li>
<li><em><strong>This equipment is for indoor use only. </strong></em></li>
<li>The manufacturer is NOT liable in the event of equipment failure due to deficient capacity calculation or lack of maintenance.</li>
</ul>
</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16362</post-id>	</item>
		<item>
		<title>Vacuum Bacterial Filters</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-vacuum/vacuum-bacterial-filters/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 22 Jun 2023 16:12:23 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=13264</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-963719 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-511684 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-403200 kc_text_block">
<p><strong>Vacuum Bacterial Filters &#8220;By pass&#8221; protection system arrange for medical vacuum pumps, compliance with NFPA99 and another Codes.</strong></p>
<section class="kc-elm kc-css-26505 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-662710 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-521584 kc_text_block">
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/mils-logo-pequeno.png" alt="" width="85" height="52" />Vacuum Bacterial Filters:</strong></p>
<ul>
<li>Brand MILS made in France.</li>
<li>Certification: C E</li>
<li>Covered with a deflector that captures solid and liquid particles.</li>
<li>The cartridge is filled with Borosilicate microfiber.</li>
<li>Filtration rate that prevents the penetration of live bacteria and microorganisms.</li>
<li>Complement with the &#8220;sodium flame test&#8221;.</li>
</ul>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/cropped-logo-sencillo.png" alt="" width="132" height="51" />Housing Specification:</strong></p>
<ul>
<li>Made of an opaque pot-filter in witch a cartridge for bacteria with a baffle is intalled.</li>
<li>Filter opacity prevents bacterial proliferation in the cartridge.</li>
<li>Gravity make particles fall to the bottom of the filter (to a lower bottle)</li>
<li>Bottle of sterilisable transparent PYREX made mounted in the bottom of the filter housing.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Medical, exclusive to Clinics and Hospitals.</strong></li>
</ul>
<p><strong>Compliance Regulation:</strong></p>
<ul>
<li>NFPA99</li>
<li>Sodium Test Flame</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be provide vacuum delivery in SFCM (Standart Cubic Feet per Minute). Indoor Use Only. <strong style="color: #ff0000;">Factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance. </strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13264</post-id>	</item>
		<item>
		<title>Medical Air Screw Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/medical-air-screw-compressor-system/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Fri, 10 Feb 2023 14:36:10 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=12890</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-10027 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-476084 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-440791 kc_text_block">
<p><strong>Screw water lubricated type Oilfree Medical Air Compressor System Arigmed’s  meeting NFPA99 and other Codes.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/denair-logo.png" alt="" width="91" height="24" />Screw water lubricated Type Oilfree Compressors:</strong></p>
<ul>
<li>Water lubricated &#8220;Oil Free&#8221; screw compressors made of stainless steel, high temperature resistant bearings, compression units made in Germany in STAINLESS STEEL.</li>
<li><strong>50-55 PSI workimg pressure. </strong></li>
<li><strong>152 PSI maximum pressure</strong>.</li>
<li>Soundproofing booth powder coating finish.</li>
<li>Transmission by pulleys and bands with a standard 220v 60htz electric motor, (other voltages must be specified in advance to the factory).</li>
<li>ISO 8571-1:2010 Equipment certificate.</li>
</ul>
<p><strong>Filter System:</strong></p>
<ul>
<li>Moisture filters with element saturation reader and automatic drain.</li>
</ul>
<p><strong>Electric After Coolers:</strong></p>
<ul>
<li>Refrigerated air cooling After-Coolers with 220V electric motor and made of stainless steel, copper tubing and aluminum heat sinks, includes a multiple connection block with relief, anti-return and automatic valves, moisture filter.</li>
</ul>
<p><strong>Moist Air Storage Tank:</strong></p>
<ul>
<li>Air Storage Vessel manufactured with ASME specifications, 120 gallon capacity in vertical configuration.</li>
<li>ASME stamped by the manufacturer.</li>
<li>Manual and automatic drains.</li>
<li>Level Valve.</li>
</ul>
<p><strong>Refrigerated Air Dryers:</strong></p>
<ul>
<li>Refrigerated dryer system for air treatment, includes pre-filters and post-filters.</li>
</ul>
<p><strong>Dry Air Storage Tank:</strong></p>
<ul>
<li>Air Storage Vessel manufactured with ASME specification, 240 gallon capacity in vertical configuration.</li>
<li>ASME stamped by the manufacturer.</li>
<li>Manual and automatic drains.</li>
<li>Level Valve.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electric-electronic control panel to coordinate the alternation, simultaneous use and stop functions, as well as the control of the Regeneration Air treatment system.</li>
<li>NFPA99 specified alarm detection and maintenance alert, NEMA12 class enclosure.</li>
<li>7” (inches) touch screen for control and visualization of the operation status of the compressor.</li>
</ul>
<p><strong>Regenerative Air Dryers:</strong></p>
<ul>
<li>Electrical valves Normally open, timed and controlled by the equipment control panel, drying temperature of -40°C, are included in the system in duplicate.</li>
</ul>
<p><strong>Medical air Filter System:</strong></p>
<ul>
<li>Filters or moisture traps, 1 micron particle filter, optional anti-bacterial filters and final line regulator are included in the system in duplicate.</li>
</ul>
<p><strong>Air Quality Monitors:</strong></p>
<ul>
<li>Monitor for High Level Detection of Carbon Monoxide.</li>
<li>Monitor for detection of high level of dew point.</li>
</ul>
<p><strong>Data Relay Output:</strong></p>
<ul>
<li>One relay output (dry contacts) for alarm transmission and connection to the master alarm panel for source equipment.</li>
</ul>
<p><strong>Designed for Use:</strong></p>
<ul>
<li>Exclusively Medical in Clinics and Hospitals.</li>
</ul>
<p><strong>Compliance Regulations:</strong></p>
<ul>
<li>NFPA99</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>System Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="123" height="49" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in CFM (standard cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in CFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12890</post-id>	</item>
		<item>
		<title>Vacuum Pump oilfree claw type</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-vacuum/vacuum-pump-oilfree-claw-type/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Fri, 06 Jan 2023 17:03:29 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=12491</guid>

					<description><![CDATA[<img class=" wp-image-9635 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/made-in-france-2021-150x150.png" alt="" width="90" height="90" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-457377 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-863155 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-610459 kc_text_block">
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/mils-logo-pequeno.png" alt="" width="72" height="44" />Oilfree Claw type vacuum pump Mils, manufactured in France.</strong></p>
<section class="kc-elm kc-css-930840 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-965843 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-969162 kc_text_block">
<section class="kc-elm kc-css-662455 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-101128 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-51561 kc_text_block">
<p><strong>Available Power:</strong></p>
<ul>
<li>Oil Free Claw type: 3 HP, 5 HP, 10 HP, 15 HP.</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>Certification:</strong> <img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2022/09/LOGO-CE.png" alt="" width="85" height="60" /></p>
<section class="kc-elm kc-css-405623 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-297729 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-744518 kc_text_block">
<section class="kc-elm kc-css-768936 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-405442 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-349152 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<section class="kc-elm kc-css-74148 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-466239 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-204577 kc_text_block">
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">Replacements and parts only compatible with Mils vacuum pump´s brand. Indoor use only. <strong style="color: #ff0000;">Factory is NOT Responsible in case of equipment failure as a result of lack of maintenance.</strong></li>
</ul>
<div></div>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12491</post-id>	</item>
		<item>
		<title>Oil Lubricated Medical Vacuum Pump System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-vacuum/lubricated-medical-vacuum-pump-system/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 05 Jan 2023 16:46:32 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=12483</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-388147 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-769006 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-384079 kc_text_block">
<p><strong>Medical-Surgical Vacuum System with Oil lubricated rotary vanes, compliance with NFPA99 and another Codes.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/mils-logo-pequeno.png" alt="" width="85" height="52" />Vacuum Pumps:</strong></p>
<ul>
<li>MILS Brand Vacuum Pumps made in France <em><strong>Oil Lubricated Rotary Vane Technology</strong></em> (1.5 HP until 20 HP), EVISA Model with a 220v 60htz multi voltage direct drive electric motor, (other voltages must be notified in advance to the factory).</li>
<li>Certifications: C E</li>
</ul>
<p><strong>Vacuum Tank:</strong></p>
<ul>
<li>ASME standard Vacuum tank manufactured.</li>
<li>ASME stamped by the vacuum tank manufacturer.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electric &#8211; electronic Control Panel NEMA12 class cabinet to coordinate alternation sequences, simultaneous use and stop of vacuum pumps, as well, NFPA99 type alarms and local signals.</li>
<li>7 &#8221; (inches) color touch-screen to control and display the operating status and alarms display of the package medical vacuum system.</li>
<li>Oil levels viewer (if apply) and high temperature pumps levels.</li>
</ul>
<p><strong>Filter System:</strong></p>
<ul>
<li>Anti-bacteria filters to protect the medical vacuum system, in duplicate.</li>
<li>Particle Filter (paper cartridge) to protect each vacuum pump on the medical vacuum system.</li>
</ul>
<p><strong>Data Relay Output:</strong></p>
<ul>
<li>It includes a data relay output (dry contact) for connection with the master panel alarm source equipment.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Medical, exclusive to Clinics and Hospitals.</strong></li>
</ul>
<p><strong>Compliance Regulation:</strong></p>
<ul>
<li>NFPA99</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be provide vacuum delivery in SFCM (Standart Cubic Feet per Minute) and geographical location with height according to the sea level uder the NFPA99-2015 and 2018 code. You must specify if the equipment will be used for the evacuation of anesthetic gases (WAGD).Refer to the vacuum capacities SCFM@19&#8243;Hg in equipment´s data sheet.Indoor Use Only. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance. </strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12483</post-id>	</item>
		<item>
		<title>Vacuum Pump oil lubricated rotary vane</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-vacuum/vacuum-pump/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Tue, 06 Sep 2022 17:49:41 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=12135</guid>

					<description><![CDATA[<img class=" wp-image-9635 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/made-in-france-2021-150x150.png" alt="" width="90" height="90" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-959798 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-388337 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-12230 kc_text_block">
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/mils-logo-pequeno.png" alt="" width="70" height="43" />Oil Lubricated Rotary Vane vacuum pump Mils, manufactured in France.</strong></p>
<section class="kc-elm kc-css-662455 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-101128 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-51561 kc_text_block">
<p><strong>Available Power:</strong></p>
<ul>
<li>Lubricated Rotary Vane: 1.5 HP, 3 HP, 5 HP, 7.5 HP, 10 HP, 15 HP, 18 HP, 20 HP.</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>Certification:</strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2022/09/LOGO-CE.png" alt="" width="83" height="59" /></p>
</div>
<div class="kc-elm kc-css-51561 kc_text_block">
<section class="kc-elm kc-css-405623 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-297729 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-744518 kc_text_block">
<section class="kc-elm kc-css-768936 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-405442 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-349152 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<section class="kc-elm kc-css-74148 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-466239 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-204577 kc_text_block">
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">Replacements and parts only compatible with Mils vacuum pump´s brand. Indoor use only. <strong style="color: #ff0000;">Factory is NOT Responsible in case of equipment failure as a result of lack of maintenance.</strong></li>
</ul>
<div></div>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12135</post-id>	</item>
		<item>
		<title>Oil Free Scroll Air Compressor</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oilfree-scroll-air-compressor-eng_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 18 Apr 2022 15:15:31 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=11535</guid>

					<description><![CDATA[<img class=" wp-image-13079 alignleft" src="https://arigmed.com/wp-content/uploads/2022/04/MADE-IN-JAPAN.jpg" alt="" width="93" height="116" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-39289 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-809427 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-69886 kc_text_block">
<p><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/hitachi-logo-transparente-oem.png" alt="" width="81" height="29" /><strong>Oil Free Scroll Air Compressor.</strong></p>
<ul>
<li><strong><em>Housing:</em></strong> Natural aluminium foundry.</li>
<li><strong><em>Pulley: </em></strong>Carbon steel made.</li>
<li><strong>Fixed and oscillating spiral:</strong> Carbon steel made.</li>
</ul>
<p><strong>Transmission:</strong></p>
<ul>
<li><strong><em>Bearings:</em></strong> Sealed high resistence and temperature made.</li>
</ul>
<p><strong>Aftercooler:</strong></p>
<ul>
<li><em><strong>Type:</strong> Air Cooling</em></li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<div class="kc-elm kc-css-204577 kc_text_block">
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">Spare parts and parts only compatible for oil-free compressors of the Arigmed brand, Indoor use only. <strong style="color: #ff0000;">Factory is NOT Responsible in case of equipment failure as a result of lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11535</post-id>	</item>
		<item>
		<title>Screw type Oilfree Air Compressor Water Lubricated</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-screw-air-compressor-water-lubricated-eng_us/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Wed, 23 Jun 2021 17:00:19 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=8772</guid>

					<description><![CDATA[<img class="wp-image-9640 alignleft" src="https://arigmed.com/wp-content/uploads/2021/06/MADE-IN-TAIWAN-2021-300x189.png" alt="" width="140" height="88" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">@media only screen and (min-width: 1000px) and (max-width: 5000px){body.kc-css-system .kc-css-799655{width: 100%;}}</style>
<section class="kc-elm kc-css-276322 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-799655 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-883594 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Oilfree Screw Air Compressor Water Lubricated,  designed for continuous heavy duty.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/denair-logo.png" alt="" width="114" height="30" />Screw Compressors:</strong></p>
<ul>
<li>Oil-free and water-lubricated Screw System for <strong>152 psig continuous working pressure</strong>, DENAIR brand of Taiwan and stainless steel screw compressor Made in Germany, to an optimal isothermal compression and 100% oil-free air delivery.</li>
<li>Stainless Steel Filters and pipes made, to prevent materials corrosion.</li>
<li>Belt Driven Transmission, standard electric motor 220v 60htz, (other voltages must be specified in advance to the factory).</li>
<li>DENAIR Brand.</li>
<li>Compressor Certification: ISO 8573-1:2010.</li>
</ul>
<p><strong>Cabinet:</strong></p>
<ul>
<li>Silent type cabinet.</li>
</ul>
<p><strong>Air Storage Tank:</strong></p>
<ul>
<li>Air and water Storage Container stainless steel made.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electronic control panel to coordinate stop and compressor functions.</li>
<li>LCD touch screen control and display, to compressor operation status.</li>
</ul>
<p><strong>Designed for:</strong></p>
<ul>
<li>Pharmaceutical,  Laboratories and equipement test facilities.</li>
<li>Hyperbaric Chambers.</li>
<li><strong>Medical, for Oxygen and Air Production (only in addition to other systems and devices).</strong></li>
<li>Industrial (Where Oil Free Air is required).</li>
<li>Food (Where Oil Free Air is required).</li>
</ul>
<p><strong>Compliance Regulations when it´s Configured to Produce Medical Air:</strong></p>
<ul>
<li>NFPA99, only in addition to other systems and equipment for air regulation and purification</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>OilFree Air Class 0 Arigmed´s System Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="113" height="45" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in CFM (cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in CFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">Factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">8772</post-id>	</item>
	</channel>
</rss>
