<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Medical Air &#8211; arigmed</title>
	<atom:link href="https://arigmed.com/product-category/medical-air-and-vacuum-systems/medical-air/feed/" rel="self" type="application/rss+xml" />
	<link>https://arigmed.com</link>
	<description>Medical Gases Equipment Manufacturer</description>
	<lastBuildDate>Tue, 24 Feb 2026 18:11:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://arigmed.com/wp-content/uploads/2019/07/cropped-favicon-32x32.png</url>
	<title>Medical Air &#8211; arigmed</title>
	<link>https://arigmed.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">246496849</site>	<item>
		<title>Oil Free Piston Air Compressor V.1</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-piston-air-compressor-v-1/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Tue, 24 Feb 2026 17:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16479</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-781829 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-709137 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-999084 kc_text_block">
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="122" height="47" /></strong></p>
<section class="kc-elm kc-css-507874 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-645604 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-819843 kc-animated kc-animate-eff-fadeInRight kc_text_block">
<p><strong>Oil-free reciprocating (piston) compressor, one stage, V.1 model.</strong></p>
<ul>
<li>Brand <em><strong>ARIGMED.</strong></em></li>
<li>100% manufactured in <em><strong>MEXICO.</strong></em></li>
<li>Spare parts and components are compatible exclusively with ARIGMED brand equipment; the unit is intended for indoor use only.</li>
<li><strong style="color: #ff0000;">The factory is NOT responsible for equipment failure resulting from lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16479</post-id>	</item>
		<item>
		<title>Oil Free Piston Air Compressor</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-piston-air-compressor/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Sat, 02 Aug 2025 23:44:11 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16367</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-507874 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-645604 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-819843 kc-animated kc-animate-eff-fadeInRight kc_text_block">
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="122" height="47" />Oil-free reciprocating (piston) compressor, available in one and two stages.</strong></p>
<ul>
<li>Brand <em><strong>ARIGMED.</strong></em></li>
<li>100% manufactured in <em><strong>MEXICO.</strong></em></li>
<li>Spare parts and components are compatible exclusively with ARIGMED brand equipment; the unit is intended for indoor use only.</li>
<li><strong style="color: #ff0000;">The factory is NOT responsible for equipment failure resulting from lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16367</post-id>	</item>
		<item>
		<title>Medical Air Reciprocant Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/medical-air-reciprocant-compressor-system/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Sat, 02 Aug 2025 22:46:13 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16362</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-755586 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-654956 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-803598 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>Packaged system for reciprocating medical air production, Arigmed </strong></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li><em><strong>Certified under ISO 8573-1:2010 Class 0</strong></em>.</li>
<li>Complies with NFPA99.</li>
<li>To quote the equipment, the medical air consumption in SCFM (standard cubic feet per minute) is required, based on the requirements specified by the NFPA99 code.</li>
<li>Refer to the free air delivery capacity table in SCFM in the equipment&#8217;s technical datasheet.</li>
<li><em><strong>This equipment is for indoor use only. </strong></em></li>
<li>The manufacturer is NOT liable in the event of equipment failure due to deficient capacity calculation or lack of maintenance.</li>
</ul>
</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16362</post-id>	</item>
		<item>
		<title>Medical Air Screw Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/medical-air-screw-compressor-system/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Fri, 10 Feb 2023 14:36:10 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=12890</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-10027 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-476084 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-440791 kc_text_block">
<p><strong>Screw water lubricated type Oilfree Medical Air Compressor System Arigmed’s  meeting NFPA99 and other Codes.</strong></p>
<p><strong><img decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/denair-logo.png" alt="" width="91" height="24" />Screw water lubricated Type Oilfree Compressors:</strong></p>
<ul>
<li>Water lubricated &#8220;Oil Free&#8221; screw compressors made of stainless steel, high temperature resistant bearings, compression units made in Germany in STAINLESS STEEL.</li>
<li><strong>50-55 PSI workimg pressure. </strong></li>
<li><strong>152 PSI maximum pressure</strong>.</li>
<li>Soundproofing booth powder coating finish.</li>
<li>Transmission by pulleys and bands with a standard 220v 60htz electric motor, (other voltages must be specified in advance to the factory).</li>
<li>ISO 8571-1:2010 Equipment certificate.</li>
</ul>
<p><strong>Filter System:</strong></p>
<ul>
<li>Moisture filters with element saturation reader and automatic drain.</li>
</ul>
<p><strong>Electric After Coolers:</strong></p>
<ul>
<li>Refrigerated air cooling After-Coolers with 220V electric motor and made of stainless steel, copper tubing and aluminum heat sinks, includes a multiple connection block with relief, anti-return and automatic valves, moisture filter.</li>
</ul>
<p><strong>Moist Air Storage Tank:</strong></p>
<ul>
<li>Air Storage Vessel manufactured with ASME specifications, 120 gallon capacity in vertical configuration.</li>
<li>ASME stamped by the manufacturer.</li>
<li>Manual and automatic drains.</li>
<li>Level Valve.</li>
</ul>
<p><strong>Refrigerated Air Dryers:</strong></p>
<ul>
<li>Refrigerated dryer system for air treatment, includes pre-filters and post-filters.</li>
</ul>
<p><strong>Dry Air Storage Tank:</strong></p>
<ul>
<li>Air Storage Vessel manufactured with ASME specification, 240 gallon capacity in vertical configuration.</li>
<li>ASME stamped by the manufacturer.</li>
<li>Manual and automatic drains.</li>
<li>Level Valve.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electric-electronic control panel to coordinate the alternation, simultaneous use and stop functions, as well as the control of the Regeneration Air treatment system.</li>
<li>NFPA99 specified alarm detection and maintenance alert, NEMA12 class enclosure.</li>
<li>7” (inches) touch screen for control and visualization of the operation status of the compressor.</li>
</ul>
<p><strong>Regenerative Air Dryers:</strong></p>
<ul>
<li>Electrical valves Normally open, timed and controlled by the equipment control panel, drying temperature of -40°C, are included in the system in duplicate.</li>
</ul>
<p><strong>Medical air Filter System:</strong></p>
<ul>
<li>Filters or moisture traps, 1 micron particle filter, optional anti-bacterial filters and final line regulator are included in the system in duplicate.</li>
</ul>
<p><strong>Air Quality Monitors:</strong></p>
<ul>
<li>Monitor for High Level Detection of Carbon Monoxide.</li>
<li>Monitor for detection of high level of dew point.</li>
</ul>
<p><strong>Data Relay Output:</strong></p>
<ul>
<li>One relay output (dry contacts) for alarm transmission and connection to the master alarm panel for source equipment.</li>
</ul>
<p><strong>Designed for Use:</strong></p>
<ul>
<li>Exclusively Medical in Clinics and Hospitals.</li>
</ul>
<p><strong>Compliance Regulations:</strong></p>
<ul>
<li>NFPA99</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>System Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="123" height="49" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in CFM (standard cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in CFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12890</post-id>	</item>
		<item>
		<title>Oil Free Scroll Air Compressor</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oilfree-scroll-air-compressor-eng_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 18 Apr 2022 15:15:31 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=11535</guid>

					<description><![CDATA[<img class=" wp-image-13079 alignleft" src="https://arigmed.com/wp-content/uploads/2022/04/MADE-IN-JAPAN.jpg" alt="" width="93" height="116" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-39289 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-809427 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-69886 kc_text_block">
<p><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/hitachi-logo-transparente-oem.png" alt="" width="81" height="29" /><strong>Oil Free Scroll Air Compressor.</strong></p>
<ul>
<li><strong><em>Housing:</em></strong> Natural aluminium foundry.</li>
<li><strong><em>Pulley: </em></strong>Carbon steel made.</li>
<li><strong>Fixed and oscillating spiral:</strong> Carbon steel made.</li>
</ul>
<p><strong>Transmission:</strong></p>
<ul>
<li><strong><em>Bearings:</em></strong> Sealed high resistence and temperature made.</li>
</ul>
<p><strong>Aftercooler:</strong></p>
<ul>
<li><em><strong>Type:</strong> Air Cooling</em></li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<div class="kc-elm kc-css-204577 kc_text_block">
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">Spare parts and parts only compatible for oil-free compressors of the Arigmed brand, Indoor use only. <strong style="color: #ff0000;">Factory is NOT Responsible in case of equipment failure as a result of lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11535</post-id>	</item>
		<item>
		<title>Screw type Oilfree Air Compressor Water Lubricated</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/oil-free-screw-air-compressor-water-lubricated-eng_us/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Wed, 23 Jun 2021 17:00:19 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=8772</guid>

					<description><![CDATA[<img class="wp-image-9640 alignleft" src="https://arigmed.com/wp-content/uploads/2021/06/MADE-IN-TAIWAN-2021-300x189.png" alt="" width="140" height="88" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">@media only screen and (min-width: 1000px) and (max-width: 5000px){body.kc-css-system .kc-css-799655{width: 100%;}}</style>
<section class="kc-elm kc-css-276322 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-799655 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-883594 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Oilfree Screw Air Compressor Water Lubricated,  designed for continuous heavy duty.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/denair-logo.png" alt="" width="114" height="30" />Screw Compressors:</strong></p>
<ul>
<li>Oil-free and water-lubricated Screw System for <strong>152 psig continuous working pressure</strong>, DENAIR brand of Taiwan and stainless steel screw compressor Made in Germany, to an optimal isothermal compression and 100% oil-free air delivery.</li>
<li>Stainless Steel Filters and pipes made, to prevent materials corrosion.</li>
<li>Belt Driven Transmission, standard electric motor 220v 60htz, (other voltages must be specified in advance to the factory).</li>
<li>DENAIR Brand.</li>
<li>Compressor Certification: ISO 8573-1:2010.</li>
</ul>
<p><strong>Cabinet:</strong></p>
<ul>
<li>Silent type cabinet.</li>
</ul>
<p><strong>Air Storage Tank:</strong></p>
<ul>
<li>Air and water Storage Container stainless steel made.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electronic control panel to coordinate stop and compressor functions.</li>
<li>LCD touch screen control and display, to compressor operation status.</li>
</ul>
<p><strong>Designed for:</strong></p>
<ul>
<li>Pharmaceutical,  Laboratories and equipement test facilities.</li>
<li>Hyperbaric Chambers.</li>
<li><strong>Medical, for Oxygen and Air Production (only in addition to other systems and devices).</strong></li>
<li>Industrial (Where Oil Free Air is required).</li>
<li>Food (Where Oil Free Air is required).</li>
</ul>
<p><strong>Compliance Regulations when it´s Configured to Produce Medical Air:</strong></p>
<ul>
<li>NFPA99, only in addition to other systems and equipment for air regulation and purification</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>OilFree Air Class 0 Arigmed´s System Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="113" height="45" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in CFM (cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in CFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">Factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">8772</post-id>	</item>
		<item>
		<title>Instrumental Air Reciprocant Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/instrumental-air-reciprocant-compressor-system-en_us/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Tue, 28 Jul 2020 20:19:52 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/compresores-para-aire-de-instrumentos-reciprocante/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-156317 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-91643 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-143208 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Arigmed´s Oilfree Reciprocant Medical Instrumental Air Compressor System meeting with NFPA99 and another Codes.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="127" height="49" />Piston Type Olifree Compressor:</strong></p>
<ul>
<li>Two Stages Reciprocating Piston &#8220;Oil Free&#8221; compressor, aluminium and carbon steel cast made, high work and temperature resistant bearings,  compression rings and raider ring PTEF with carbon and graphite load made, <strong><em>air compressor made in Mexico</em></strong> and designed for a 160 PSI working pressure.</li>
<li>High temperature powder coating finish in black color to air compressor exterior covering.</li>
<li>Belt driven transmission with standard 220v 60htz electric motor, (other voltages must be specified in advance at the factory)</li>
<li>Easy maintenance and replacement of parts.</li>
<li style="color: #ff0000;"><strong>Made in Mexico.</strong></li>
</ul>
<p><strong>Air Refrigerated AfterCoolers:</strong></p>
<ul>
<li>Main Air Refrigerated Aftercooler carbon steel made with temperature aluminium heatsinks.</li>
<li>Secondary Air Refrigerated Aftercooler guardbelt mount type, stainless steel and copper tubing made with aluminium cooler heat sink fins, includes a multiple connection block with relief, backflow and automatic valves for each compression unit.</li>
</ul>
<p><strong>Air Vessel:</strong></p>
<ul>
<li>Air vessel under ASME specification with internal and external treatment (may include a man access hatch for maintenance and internal cleaning).</li>
<li>ASME stamped by the manufacturer (ASME stamp is only avilable for vessels without man access hatch).</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electrical-electronic control panel to coordinate  alternation, simultaneous use and stop, as well as the control of the Regeneration Air treatment system.</li>
<li>NFPA99 specified alarm detection and maintenance alert, NEMA12 class enclosure.</li>
<li>7” (inches) touch screen display to control and view of compressor operation status.</li>
</ul>
<p><strong>Regenerative Tower Air Dryers:</strong></p>
<ul>
<li>Regenerative tower dryers, with Normally open electric valves timed and controlled by the equipment control panel, drying temperature of -60°c, are included in the system in duplicate.</li>
</ul>
<p><strong>Air filter system:</strong></p>
<ul>
<li>Moisture filters, 0.01 particle filters, carbon activate filters, optional antibacterial filters and final line pressure regulator are included in the system by duplicate.</li>
</ul>
<p><strong>Air Quality Monitors:</strong></p>
<ul>
<li>High Level Carbon Monoxide detection.</li>
<li>High Level Dew Point detection.</li>
</ul>
<p><strong>Relay Outputs for Data:</strong></p>
<ul>
<li>Relay type output (dry) for alarm transmission and connection to the source master panel alarm.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Medical, exclusive to Clinics and Hospitals.</strong></li>
</ul>
<p><strong>Working pressure:</strong></p>
<ul>
<li>160 PSI.</li>
</ul>
<p><strong>Maximum pressure:</strong></p>
<ul>
<li>180 PSI.</li>
</ul>
<p><strong>Compliance Regulations:</strong></p>
<ul>
<li>NFPA99</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="123" height="49" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="63" height="63" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Instrumental Air consumption required in SCFM (standard cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in SCFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6797</post-id>	</item>
		<item>
		<title>Medical Air Scroll Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/medical-air-scroll-type-compressor-system-en_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 08 Jul 2019 07:53:51 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/compresores-para-aire-medico-de-espiral/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">body.kc-css-system .kc-css-620792.kc_title,body.kc-css-system .kc-css-620792 .kc_title,body.kc-css-system .kc-css-620792 .kc_title a.kc_title_link{text-align: center;}body.kc-css-system .kc-css-569340{text-align: center;}</style>
<section class="kc-elm kc-css-694897 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-609549 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-402922 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Arigmed´s Scroll Oilfree Medical Air Compressor System meeting with NFPA99 and another Codes.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/hitachi-logo-transparente-oem.png" alt="" width="120" height="43" />Scroll Compressors:</strong></p>
<ul>
<li>Hitachi oil-free scroll compressor, belt driven transmission, 220v, 60htz electric motor, (other voltages must be specified in advance to the factory).</li>
<li><strong>50-55 PSI working pressure.</strong></li>
<li><strong>140 PSI maximum pressure.</strong></li>
<li>Carbon steel platform powder coating finish mounted, it includes anti-vibration rubber pads.</li>
<li>Air-air type primary aftercooler at the outlet.</li>
<li>Made in Japan.</li>
</ul>
<p><strong>Air Refrigerated AfterCoolers:</strong></p>
<ul>
<li>Main air refrigerated aftercooler with block multiple connection, includes: relief, back-flow and automatic valves, humidity filter for each scroll compression unit.</li>
<li>Secondary Air Refrigerated Aftercoolers, stainless steel and copper tubing made with aluminium cooler heat sink fins, includes a multiple connection block with relief, backflow and automatic valves for each compression unit.</li>
</ul>
<p><strong>Air Vessel:</strong></p>
<ul>
<li>Air vessel under ASME specification with internal and external treatment (may include a man access hatch for maintenance and internal cleaning).</li>
<li>ASME stamped by the manufacturer (ASME stamp is only avilable for vessels without man access hatch).</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electrical-electronic control panel to coordinate  alternation, simultaneous use and stop, as well as the control of the Regeneration Air treatment system.</li>
<li>NFPA99 specified alarm detection and maintenance alert, NEMA12 class enclosure.</li>
<li>7 ” (inches) touch screen display to control and view of compressor operation status.</li>
</ul>
<p><strong>Filter System:</strong></p>
<ul>
<li>Moisure filters, 1 micron particle filters, antibacterial optionals filters and a final line pressure regulator, all systema by duplicate.</li>
</ul>
<p><strong>Air Quality Monitors:</strong></p>
<ul>
<li>High level Carbon Monoxide Monitor detection.</li>
<li>High level Dew Point detection.</li>
</ul>
<p><strong>Regenerative Air Dryer System:</strong></p>
<ul>
<li>Dual tower regenerative type dryers with normally open automatic valves controlled from the compressor system control panel, -40°c air drying temperature. Air dryer system by duplicate.</li>
</ul>
<p><strong>Relay Output Data:</strong></p>
<ul>
<li>It includes a Relay data output (dry contact) connection of the master panel alarm source equipments.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Medical, exclusive to Clinics and Hospitals.</strong></li>
</ul>
<p><strong>Compliance Regulations:</strong></p>
<ul>
<li>NFPA99</li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="118" height="47" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Medical Air consumption required in SCFM (standard cubic feet per minute) under all requires of NFPA99-2015 and 2018. Consult Delivery Capabilities of each sytem in SCFM on Technical Data Sheet. Indoor Use Only. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
<div class="kc-elm kc-css-941975" style="height: 39px; clear: both; width:100%;"></div>
<div class="kc-elm kc-css-620792 kc-title-wrap ">
<h5 class="kc_title">Medical Air Scroll Type Compressor System</h5>
</div>
<div class="kc-elm kc-css-569340 kc_shortcode kc_video_play kc_video_wrapper">
								<video width="600" height="338.98305084746" controls><source src="https://arigmed.com/wp-content/uploads/2022/05/SCROLL-COMPRESSOR.mp4" type="video/mp4">Your browser does not support the video tag.</video></p></div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5886</post-id>	</item>
		<item>
		<title>Dental Air Compressor System</title>
		<link>https://arigmed.com/tienda/medical-air-and-vacuum-systems/medical-air/dental-air-compressor-system-en_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 08 Jul 2019 07:49:16 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/compresores-para-aplicaciones-dentales/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-578989 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-669099 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-42092 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>ISO 8573-1:2010 Certified Arigmed’s Reciprocant Oil Free Dental Air Compressor System.</strong></p>
<p><strong><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2021/09/logo-sencillo.png" alt="logo arigmed" width="127" height="49" />Piston type Oilfree Compressor:</strong></p>
<ul>
<li>Oil-free <strong><em>one-stage</em></strong> piston compressors aluminum and WCB steel cast made, aluminum pistons for a <em><strong>maximum working pressure of 100 PSI</strong></em> <strong>(Compressor is NOT continuous duty)</strong>, arigmed brand with transmission by pulleys and bands with electric motor 220v 60htz; (must specify in advance to the factory).</li>
<li>Oil-free<strong><em>Two-stage</em></strong> piston compressors aluminum and WCB steel cast made, aluminum pistons for a <em><strong>maximum working pressure of 160-170 PSI</strong></em> <strong>(Compressor is NOT continuous duty)</strong>, arigmed brand with pulley transmission and bands with electric motor 220v 60htz; (must specify in advance to the factory).</li>
<li style="color: #ff0000;"><strong>Made in Mexico.</strong></li>
</ul>
<p><strong>Air Refrigerated AfterCoolers:</strong></p>
<ul>
<li>Air Refrigerated Aftercoolers guard belt type, includes a multiple connection block with relief, backflow and automatic valves for each compression unit.</li>
</ul>
<p><strong>Air Vessel:</strong></p>
<ul>
<li>Air vessel under ASME specification with internal and external treatment (may include a man access hatch for maintenance and internal cleaning).</li>
<li>ASME stamped is not inlcuded in this air compressor system.</li>
</ul>
<p><strong>Control Panel:</strong></p>
<ul>
<li>Electrical-electronic control panel to coordinate  alternation, simultaneous use and stop, as well as the control of the Regeneration Air treatment system.</li>
</ul>
<p><strong>Regenerative Tower Air Dryers:</strong></p>
<ul>
<li>Regenerative tower dryers, with Normally open electric valves timed and controlled by the equipment control panel, drying temperature of -40°c.</li>
</ul>
<p><strong>Air filter system:</strong></p>
<ul>
<li>Moisture filters, 1 micron particle filter and final line regulator are included in the system.</li>
</ul>
<p><strong>Designed for Use: </strong></p>
<ul>
<li style="color: #ff0000;"><strong>Dental exclusive.</strong></li>
</ul>
</ul>
<p><strong> Installation, Operation and Maintenance Equipment Manuals:</strong></p>
<ul>
<li>Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site <a href="https://arigmed.com/equipment-manuals-maintenance-aftersales-section/" target="_blank" rel="noopener">click here</a> ,and then complete the requested form.</li>
</ul>
<p><strong>Certificates:</strong></p>
<div>
<div><img loading="lazy" decoding="async" class=" alignleft" src="https://arigmed.com/wp-content/uploads/2023/01/ISO-857312010-2023.png" alt="" width="111" height="44" /></div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter" src="https://arigmed.com/wp-content/uploads/2019/07/ATENCION.png" alt="" width="91" height="91" /></div>
<ul>
<li style="text-align: center;">To quote, user must be inform about Dental Air consumption required in SCFM (standard cubic feet per minute). Consult Delivery Capabilities of each sytem in SCFM on Technical Data Sheet. Indoor Use Only. Compression is not designed for continuous use, it requires cooling periods due to lack of oil lubrication, therefore the use of two or more compression units in the system and an alternate work configuration between the compressors is recommended. <strong style="color: #ff0000;">The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment and lack of maintenance.</strong></li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5880</post-id>	</item>
	</channel>
</rss>