<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Medical Gas Control Equipments &#8211; arigmed</title>
	<atom:link href="https://arigmed.com/product-category/medical-gases/feed/" rel="self" type="application/rss+xml" />
	<link>https://arigmed.com</link>
	<description>Medical Gases Equipment Manufacturer</description>
	<lastBuildDate>Fri, 01 Aug 2025 18:34:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://arigmed.com/wp-content/uploads/2019/07/cropped-favicon-32x32.png</url>
	<title>Medical Gas Control Equipments &#8211; arigmed</title>
	<link>https://arigmed.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">246496849</site>	<item>
		<title>Master Valve</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-manifolds/accessories-for-medical-gas-manifolds/master-valve/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Fri, 01 Aug 2025 18:33:40 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16352</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">body.kc-css-system .kc-css-236999.kc_title,body.kc-css-system .kc-css-236999 .kc_title,body.kc-css-system .kc-css-236999 .kc_title a.kc_title_link{color: #1e73be;text-align: center;}body.kc-css-system .kc-css-711209{text-align: center;}</style>
<section class="kc-elm kc-css-662167 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-789374 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-277555 kc_text_block">
<p><strong>Master Valve for Medical Gases, compliant with ASTM B819 (clean for oxygen use) and NFPA99.</strong></p>
<ul>
<li>Compliant with NFPA99 standard.</li>
<li>Compliant with ASTM B819 code (clean for oxygen use).</li>
<li>Operating and maintenance personnel must be certified for safe equipment handling.</li>
<li>The quality and purity grade of medical gases, as well as the condition of containers and their connections, shall always be the responsibility of the supplier.</li>
<li><strong>The manufacturer disclaims any liability for damages to persons or property caused by misuse or improper installation of the equipment.</strong></li>
<li><strong>Wall or structural mounting brackets are not included.</strong></li>
<li><strong>Materials may suffer severe corrosion if exposed to tropical or high-humidity climates.</strong></li>
<li>Do not use oil or oil-based products.</li>
</ul>
</div>
<div class="kc-elm kc-css-770660" style="height: 24px; clear: both; width:100%;"></div>
<div class="kc-elm kc-css-236999 kc-title-wrap ">
<h5 class="kc_title">Master valve pressure test</h5>
</div>
<div class="kc-elm kc-css-322604" style="height: 30px; clear: both; width:100%;"></div>
<div class="kc-elm kc-css-711209 kc_shortcode kc_video_play kc_video_wrapper">
								<video width="600" height="338.98305084746" controls><source src="https://arigmed.com/wp-content/uploads/2023/10/prueba-de-presion-master-valve.mp4" type="video/mp4">Your browser does not support the video tag.</video></p></div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16352</post-id>	</item>
		<item>
		<title>Medical Gas Pipeline Valve</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-valves/medical-gas-pipeline-valve/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Fri, 01 Aug 2025 16:43:26 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16348</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css">body.kc-css-system .kc-css-878160.kc_title,body.kc-css-system .kc-css-878160 .kc_title,body.kc-css-system .kc-css-878160 .kc_title a.kc_title_link{text-align: center;}body.kc-css-system .kc-css-978810{text-align: center;}</style>
<section class="kc-elm kc-css-702863 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-725072 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-821748 kc_text_block">
<p><strong>Shut-off valve with copper extensions to install in medical gas pipelines.</strong><strong style="text-align: justify;"> </strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Complies with NFPA99.</li>
<li>Complies with ASTM B819 (clean for oxygen use).</li>
<li>Do not use chlorine or its derivatives, as they may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
<div class="kc-elm kc-css-957211" style="height: 35px; clear: both; width:100%;"></div>
<div class="kc-elm kc-css-878160 kc-title-wrap ">
<h5 class="kc_title">Pressure valve test</h5>
</div>
<div class="kc-elm kc-css-319796" style="height: 20px; clear: both; width:100%;"></div>
<div class="kc-elm kc-css-978810 kc_shortcode kc_video_play kc_video_wrapper">
								<video width="600" height="338.98305084746" controls><source src="https://arigmed.com/wp-content/uploads/2022/06/video-prueba-hermeticidad-de-valvulas.mp4" type="video/mp4">Your browser does not support the video tag.</video></p></div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16348</post-id>	</item>
		<item>
		<title>Twin Medical Gas Outlet with Flowmeter integrated and Diss</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/twin-medical-gas-outlet-with-flowmeter-integrated-and-diss/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 20:48:26 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16345</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-680840 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-60410 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-229179 kc_text_block">
<p style="text-align: justify;"><strong style="text-align: justify;">Outlet-Inlet for medical gas distribution <strong>with integrated flowmeter (Non-removable) and secondary outlet with threaded DISS CGA-V5 connector (Diameter Indexed Safety System)</strong></strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Complies with NFPA 99.</li>
<li>The standardization and normalization of the connector corresponds to a &#8220;threaded&#8221; coupling, offering greater safety and reliability, and complying with CGA-V5 (Compressed Gas Association) specifications for non-interchangeable gas safety connectors by diameter DISS (Diameter Indexed Safety System).</li>
<li>The use of the dual outlet with integrated secondary equipment prevents hospital operating and maintenance staff from worrying about compatibility between secondary oxygen and medical air dosing equipment and the type of inlet or coupling on wall outlets and patient headwalls. Therefore, all types of connectors or couplings for oxygen and medical air outlets will be standardized to a single connector type.</li>
<li>Prevents accidental loss of oxygen and air flowmeters due to frequent handling during connection and disconnection, since &#8220;Non-removable&#8221; flowmeters will remain permanently coupled to the oxygen and medical air outlets.</li>
<li>The use of the secondary DISS outlet allows simultaneous flow supply to other medical devices and equipment by connecting additional flowmeters, hoses, and regulator valves.</li>
<li>Compatible with U.S. brands.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
<li>Manufactured in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16345</post-id>	</item>
		<item>
		<title>Wall Mounting Box Medical Gas Outlet</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/wall-mounting-box-medical-gas-outlet/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 20:23:31 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16343</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-783675 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-147129 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-188627 kc_text_block">
<p><strong>Surface-mounted wall box for medical gas outlets.</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Complies with NFPA 99.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
<li>Manufactured in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16343</post-id>	</item>
		<item>
		<title>Screw Connect Medical Gas Outlet Plarre type (only to Mexico)</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/screw-connect-medical-gas-outlet-plarre-type-only-to-mexico/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 19:50:38 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16341</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-332815 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-710224 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-572827 kc_text_block">
<p><strong style="text-align: justify;">Outlet-Inlet for medical gas distribution with threaded plug type PLARRE (Mexico only).</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Complies with NFPA 99.</li>
<li>Quick plug compatible with PLARRE technology.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
<li>Manufactured in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16341</post-id>	</item>
		<item>
		<title>Screw Connect DISS CGA-V5 Medical Gas Outlet USA</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/screw-connect-diss-cga-v5-medical-gas-outlet-usa/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 19:36:08 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16339</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-918102 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-201901 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-995032 kc_text_block">
<p><strong style="text-align: justify;">Outlet-Inlet for medical gas distribution with threaded coupling type DISS CGA V5, thread-specific fixation for each gas.</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Compliance with NFPA 99, CGA V5, <em><strong>NBR 12188</strong></em></li>
<li>With <strong>U.L. (Under Writers Laboratories)</strong> certification</li>
<li>Threaded coupling compatible with DISS CGA V5 technology.</li>
<li>Compatible with U.S. and Brazilian brands.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
<li>Manufactured in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16339</post-id>	</item>
		<item>
		<title>Quick Connect Medical Gas Outlet MC70 (Swedish type) + M24 screw Secondary Equipment Lock Device</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/quick-connect-medical-gas-outlet-mc70-swedish-type-m24-screw-secondary-equipment-lock-device/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 19:18:28 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16337</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-853469 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-824211 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-396264 kc_text_block">
<p><strong style="text-align: justify;">Outlet-Inlet for medical gas distribution with quick coupling type MC70 (Swedish) + M24 threaded lock for securing secondary equipment.</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Compliance with NFPA 99, ASTM B819, SS EN 8752430, and SS EN ISO 9170-1</li>
<li>Quick coupling compatible with MC70 (Swedish) technology + M24 threaded lock for securing secondary equipment.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or its derivatives.</li>
<li>Manufactured in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16337</post-id>	</item>
		<item>
		<title>Quick Connect Medical Gas Outlet MC70 (Swedish type)</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/quick-connect-medical-gas-outlet-mc70-swedish-type/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 18:53:48 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16335</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-321003 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-507431 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-116427 kc_text_block">
<p><strong style="text-align: justify;">Outlet-Inlet for medical gas distribution with quick-connect MC70 (Swedish) type, with stepped inlet for each specific gas.</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Compliance with NFPA 99, ASTM B819, SS EN 8752430, and SS EN ISO 9170-1</li>
<li>Quick-connect compatible with MC70 (Swedish) technology.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metallic parts.</li>
<li>Do not use oil or oil-based products.</li>
<li>Made in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16335</post-id>	</item>
		<item>
		<title>Quick Connect Medical Gas Outlet Puritan Bennet USA</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-outlets/medical-gas-outlet-puritan-bennet-usa/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 18:04:11 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16333</guid>

					<description><![CDATA[<img class=" wp-image-9592 alignleft" src="https://arigmed.com/wp-content/uploads/2021/08/LOGO-HECHO-MEXICO-TRANSPARENTE.png" alt="" width="112" height="104" />
<p style="text-align: justify;">*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).</p>
**We always request clear specifications to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-947334 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-421645 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-629904 kc_text_block">
<p style="text-align: justify;"><strong>Outlet-Inlet for medical gas distribution with quick-connect PURITAN BENNET type, geometric inlet mount for each specific gas.</strong></p>
<section class="kc-elm kc-css-355873 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-95522 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-972603 kc_text_block">
<ul>
<li>Compliace with NFPA 99.</li>
<li>Quick-connect compatible with PURITAN BENNET technology.</li>
<li>Compatible with U.S. brands.</li>
<li>Do not use chlorine or its derivatives; may cause corrosion on metal parts.</li>
<li>Do not use oil or oil-based products.</li>
<li>Made in Mexico, ARIGMED.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">16333</post-id>	</item>
		<item>
		<title>Combination Alarm</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-alarms/combination-alarm/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Wed, 21 May 2025 20:47:20 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=16128</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-1860 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-21208 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-366506 kc_text_block">
<p style="text-align: justify;"><strong>Combination alarm consists of a zone or area alarm for real-time detection of high and low pressure events, and a master alarm for detecting abnormal conditions through a relay system—integrated into a single surface-mounted wall cabinet. It includes:</strong></p>
<ul>
<li>A digital zone or area alarm with modules for medical gases and segment-type numeric display in green color</li>
<li>An electromechanical master alarm with a dry-contact relay system</li>
<li>Real-time pressure and vacuum display on the zone or area alarm</li>
<li>Visual and audible indicators for abnormal events on the relay system alarm</li>