<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Semi Automatic Medical Gas Manifolds &#8211; arigmed</title>
	<atom:link href="https://arigmed.com/product-category/medical-gases/medical-gas-manifolds/semi-automatic-medical-gas-manifolds/feed/" rel="self" type="application/rss+xml" />
	<link>https://arigmed.com</link>
	<description>Medical Gases Equipment Manufacturer</description>
	<lastBuildDate>Wed, 25 Mar 2026 20:44:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://arigmed.com/wp-content/uploads/2019/07/cropped-favicon-32x32.png</url>
	<title>Semi Automatic Medical Gas Manifolds &#8211; arigmed</title>
	<link>https://arigmed.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">246496849</site>	<item>
		<title>Hybrid type Semiautomatic Medical Gas Manifold</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-manifolds/semi-automatic-medical-gas-manifolds/hybrid-type-semi-automatic-medical-gas-manifold-eng_us/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Thu, 03 Dec 2020 17:12:15 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=8106</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-967387 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-547209 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-22235 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p style="text-align: justify;"><strong>HYBRID-type medical gas semi-automatic type manifold, indoor use only.</strong></p>
<section class="kc-elm kc-css-943434 kc_row">
<div class="kc-row-container kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-153680 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-47828 kc_text_block">
<ul>
<li>Complies with NFPA99 standard.</li>
<li>Complies with ASTM B819 code (oxygen-clean).</li>
<li><strong>Primary bank with Deward-type cylinders and secondary bank with high-pressure gas cylinders.</strong></li>
<li><strong>Initial cylinder bank changeover occurs automatically by pressure differential with manual selector (lever) assigning primary and secondary banks for working cycles; subsequent changeovers are manual.</strong></li>
<li>Deward cylinder evaporators must function adequately under high oxygen demand to avoid manifold freezing due to inefficient liquid evaporation.</li>
<li>Use of an external vaporizer with sufficient capacity must be implemented when Deward cylinder evaporators are insufficient.</li>
<li>Operation and maintenance personnel must be certified to safely operate the equipment.</li>
<li>The quality and purity grade of medical gases and the condition of cylinders and connections are always the supplier&#8217;s responsibility.</li>
<li>Do not use oil or oil-derived products.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">8106</post-id>	</item>
		<item>
		<title>Deward type Semiautomatic Medical Gas Manifold</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-manifolds/semi-automatic-medical-gas-manifolds/deward-type-semi-automatic-medical-gas-manifold-us_en/</link>
		
		<dc:creator><![CDATA[Mario Simon]]></dc:creator>
		<pubDate>Wed, 14 Oct 2020 13:36:33 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/?post_type=product&#038;p=7706</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-587925 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-385132 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-751491 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>DEWARD-Type Semi-Automatic Manifold indoor use only.</strong></p>
<ul>
<li>Complies with NFPA99 standard.</li>
<li>Complies with ASTM B819 code (oxygen-clean).</li>
<li><strong>Initial cylinder bank switchover is automatic via pressure differential and manual selector lever designating primary and secondary banks for work cycles; subsequent switches are manual.</strong></li>
<li>Deward cylinder evaporators must function properly during high oxygen demand to prevent manifold freezing caused by inefficient liquid evaporation.</li>
<li>If Deward evaporators are insufficient, an external vaporizer with sufficient consumption capacity must be implemented.</li>
<li>Operation and maintenance personnel must be certified for safe equipment handling.</li>
<li>The quality and purity level of medical gases, as well as the condition of the containers and their connections, is always the supplier&#8217;s responsibility.</li>
<li>Do not use oil or derivatives.</li>
</ul>
<hr />
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">7706</post-id>	</item>
		<item>
		<title>Medical Gas Semiautomatic Manifold</title>
		<link>https://arigmed.com/tienda/medical-gases/medical-gas-manifolds/semi-automatic-medical-gas-manifolds/medical-gas-semiautomatic-manifold-en_us/</link>
		
		<dc:creator><![CDATA[Katia Robledo]]></dc:creator>
		<pubDate>Mon, 08 Jul 2019 06:04:37 +0000</pubDate>
				<guid isPermaLink="false">https://arigmed.com/product/manifold-semiautomatico/</guid>

					<description><![CDATA[<img class="alignleft wp-image-13078 " src="https://arigmed.com/wp-content/uploads/2023/05/MADE-IN-MEXICO-LOGO-A-LA-MITAD-300x169.gif" alt="" width="133" height="75" />
<p style="text-align: justify;">*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).</p>
*We always require clear specifications in order to make a formal quote.]]></description>
										<content:encoded><![CDATA[<style type="text/css"></style>
<section class="kc-elm kc-css-669279 kc_row">
<div class="kc-row-container  kc-container">
<div class="kc-wrap-columns">
<div class="kc-elm kc-css-173082 kc_col-sm-12 kc_column kc_col-sm-12">
<div class="kc-col-container">
<div class="kc-elm kc-css-405424 kc-animated kc-animate-eff-fadeInLeft kc_text_block">
<p><strong>Medical Gas semi-automatic type manifold indoor use only.</strong></p>
<ul>
<li>Complies with NFPA99 standard.</li>
<li>Complies with ASTM B819 code (oxygen-clean).</li>
<li><strong>Initial bank exchange is automatic, triggered by pressure differential and designated main/secondary bank; subsequent exchanges are manual using the selector lever.</strong></li>
<li>Operation and maintenance personnel must be certified to ensure safe use.</li>
<li>The supplier is always responsible for the quality and purity grade of medical gases as well as the condition of containers and connections.</li>
<li>Do not use oil or oil-based substances.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</section>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4657</post-id>	</item>
	</channel>
</rss>
