Instrumental Air Reciprocant Compressor System

Warning:

To quote, user must be inform about instrumental Air consumption required in SCFM (standard cubic feet per minute) under all requires of NFPA99-2015.

Consult Delivery Capabilities of each sytem in SCFM on Technical Data Sheet.

The factory is not responsible in the case of equipment failure due to wrong calculation to size the equipment.

Descripción

Reciprocant Medical Instrumental Air System Arigmed’s in compliance with NFPA99-2015.

Reciprocating Compressors:

  • Cast steel case two stages reciprocating compressors with aluminum pistons designed for 180 PSI working pressure.
  • Belt driven transmission with standard 220v 60htz electric motor, (other voltages must be specified in advance at the factory)
  • Easy maintenance and replacement of parts.

Air-to-Air AfterCoolers:

  • Two Air-to-Air Aftercoolers made of stainless steel and copper tubing, include a multiple connection block with relief, backflow and automatic valves for each compression unit.

Air Storage Tank:

  • Air tank container Storage under ASME specification with internal and external treatment (may include a manhole for maintenance and internal tank cleaning).
  • ASME stamped by the manufacturer.

Control Panel:

  • Electrical-electronic control panel to coordinate  alternation, simultaneous use and stop, as well as the control of the Regeneration Air treatment system. NFPA99-2015 specified alarm detection and maintenance alert, NEMA12 class enclosure.
  • 7 ”touch screen display for control and view of compressor operation status.

Regenerative Tower Air Dryers:

  • Regenerative tower dryers, with Normally open electric valves timed and controlled by the equipment control panel, drying temperature of -60°c, are included in the system in duplicate.

Air filter system:

  • Moisture filters, particle filter, antibacterial filters, final line regulator are included in the system in duplicate.

Air Quality Monitors:

  • High Level Carbon Monoxide detection.
  • High Level Dew Point detection.

Relay Outputs for Data:

  • Relay type output (dry) for alarm transmission and connection to the source master panel alarm.

Indoor use only, manufactured in Mexico.

Specifications

Systems Included:
  • Two Air type aftercoolers by each compressor
  • Automatic valve systems to prevent back flow
  • High temperature detection system for each cylinder of the compressor unit
  • Automatic valve system for moisture purges
  • AIR DRYING System twin tower regenerative type
  • AIR FILTRATION System
  • Dew Point and Carbon Monoxide monitors
  • Relay output for data extraction
  • 180 psi Maximum working pressure
Configurations:
  • Duplex
  • Triplex
  • Quatruplex
  • Quintuplex
Electric Motor Power:
  • 10 HP
  • 15 HP