10″ Display SERIE 2 Medical Gas Alarm Zone

*To a quote contact our technical and sales advisors. Your information must be valid and true (name, full address, email, phone number, country, postal code, I.D. tax status).

*We always require clear specifications in order to make a formal quote.

Description

Digital area alarm for real-time detection of high and low pressure of medical gases and low vacuum level – model SERIES 2 – featuring a 10" full-color LCD display and available internet connectivity for remote viewing. Includes:

  • Real-time display of pressure and vacuum levels for each medical gas and vacuum module in every zone or area alarm.
  • Internet monitoring (via internet connection and a serial network of alarm groups), enabling the user to receive real-time email notifications triggered by alarm events within the medical gas system.
  • Visual and audible signals for abnormal events on screen.
  • Compliance with NFPA99 standard.
  • Available in a cabinet for recessed or surface wall installation (must be specified in advance to the manufacturer).

10" Display SERIE 2 Medical Gas Alarm Zone

Specifications

⚙️ Technical Specifications. 🔧 Cabinet:
  • Manufactured by injection molding of high-resistance ABS thermoplastic compliant with NFPA 286.
  • Finished in white color.
  • Installation options: recessed or surface wall mount (must be specified to the manufacturer).
🔢 Alarm Capacity (Number of gases):
  • Configurable on screen from 1 up to 8 medical gas and vacuum modules per alarm.
  • Maximum network capacity: up to 127 gas or surgical vacuum sensors connected to the master panel.
💡 Graphics and Visual Signals
    • Real-time reading of pressure and vacuum via 10″ full-color LCD display.
    • NFPA99 color option and nomenclature for each medical gas.
    • ISO color option and nomenclature for each medical gas.
    • Alarm flashing per gas module (on display).
    • Visualization of disconnections and cross-wiring of medical gas sensors.
    • Display of area name where the zone alarm will be located.
    • Possibility to duplicate any gas and/or vacuum module without exceeding the maximum limit of 8 modules.
🚨 Alarm Events
        • Alarm for real-time detection of high and low pressure and low vacuum levels.
        • Alarm for signal interruption in medical gas and vacuum sensors (disconnection).
        • Alarm for detection of sensor exchange or cross-wiring in medical gas and vacuum lines.
        • Screen warning when alarm activation parameters do not match those specified by NFPA99.
🔌 Communications
        • RJ45 female ports for data input and output.
        • Dry contact relay output port (1 port).
        • RS485 communication protocol via SERIAL connection for linkage with zone alarm groups and the Arigmed SERIES 2 master alarm panel.
        • Connection to INTRANET and EXTRANET (INTERNET) through the ARIGMED ETHERNET INTERFACE with HTML to view the system from remote devices such as PC, TABLET, SMARTPHONE via website.
🏭 User Functions and Modifications
        • User-modifiable parameters: unit change (psi or bar), pressure cutoff levels, and hysteresis.
        • Edit the name of the area where the zone alarm will be installed.
🎛️ Controls
        • Display button to mute alarm sound (automatic reset after 1 hour if pressure doesn’t normalize).
        • System test button on display.
📘 Installation, Operation and Maintenance Manual
        • Protected document, exclusive to branded equipment.
        • Request via email and form in the manuals and after-sales service section.
🔗 Required Complementary Equipment
        • Remote digital pressure/vacuum sensor connected to medical gas network.
        • Check valve DISS DEMAND CGA V-5 installed in supply piping.
        • Flush-mount box for electrical, data, and medical gas/vacuum connections.
        • Belden cable STP #8461ZH or #8208 for additional relay port (point-to-point connection, no splicing for relay system).
        • Minimum UTP CAT 6 data cable for serial connection to segment alarms (point-to-point, no splicing).
        • Electrical supply: 110–220V, 50–60 Hz.
        • Arigmed Ethernet Interface for HTML. Arigmed website for remote pressure system monitoring. (User system hosting on ARIGMED monitoring site may incur additional costs).
        • High-quality, fixed Internet access required.
⚠️ Avoidable Impacts
        • Voltage variations in electrical supply.
        • Use of emergency power supply generators as primary source.
        • Intermittent or unstable electrical supply.
        • Frequent power loss with repeated emergency generator activation.
🛠️ Installation Recommendations
      • Verify physical grounding connection.
      • Install backup power system (No-Break).
      • Install surge suppressor for electrical discharge protection.

Brochure

Download:
No Available  

Internet Alarm Surveillance System

🔔 Enhanced Version:
    Our alarm system allows real-time visualization over the internet. From the pressure registered in each connected gas module to the statistical history of alarm events by defined periods—everything is instantly available.
    In addition, the system can send alerts and notifications via email and is accessible from any internet-connected device—whether a smartphone, tablet, or computer—through our website.

Select to go to the Link:
Link to Medical Gas Alarm Monitoring System
Intellectual and industrial property: All rights reserved.
  • All access to this website is subject to the following conditions: The reproduction, permanent storage and dissemination of the contents or any other use that has a public or commercial purpose is forbidden without prior written notice and approval of Grupo Arigmed S. de R.L. de C.V.
  • All documents, images and contents, on this website are from the Intellectual property of Grupo Arigmed S. de R.L. de C.V., any type of copy, plagiarism or similarity in those (documents, images and contents), will be object of legal actions to avoid its use by unauthorized persons, organizations or companies, as well to compensate author´s damage caused.