Description
Combination alarm includes a high and low pressure detection alarm with a green numerical segment display and an electromechanical master panel alarm relay type. Available only in a wall-mounted enclosure, meeting NFPA 99.
Cabinet:
- Cabinet manufactured from special extruded aluminum profiles, 6063 temper 5 alloy, powder coating finish.
- Wall-mounted only.
Gases numeber for numerical segment alarm:
- 1 to 6 medical gases modules contained in alarm enclosure.
Graphics and Visual:
- Real-time display of readings on the numerical segment display in green for pressure and vacuum.
- High-visibility green LEDs for normal status.
- High-visibility red LEDs with intermittent flashing for high and low pressure alarm events.
- Numerical display with “ERROR" code for disconnections and cross-connections of medical gas sensors.
- High-visibility green LED to indicate that the alarm is energized.
Alarm Events:
- Alarm for the detection of high and low pressure events in real time.
- Alarm for the detection of signal interruption in the sensors (disconnection).
- Alarm for the detection of medical gas sensor swapping or cross-connection.
Communications:
- 1 Relay port (dry contacts) per alarm cabinet.}
- RS485 communication protocol via serial connection for linking with zone alarm groups and with the Arigmed SERIES 2 Relay master alarm panel (source equipment).
Factory adjusts:
- PSI standard units; to BAR, must be requested to the factory in advance.
Controls:
- A push-button audible alarm cancellation, with a reset after 1 hour if the pressure or vacuum has not returned to normal.
- A push-button alarm system test.
Master Panel Relay type Alarm:
Number of Signals:
- In multiples of 10-signal modules and up to 60 signals contained in a single master relay alarm panel cabinet (minimum 10 signals and maximum 60 signals for a single cabinet).
Visual and Audio Signals:
- High-visibility green LEDs for normal status on each signal module.
- High-visibility red LEDs for alarm events on each signal module.
- High-visibility green LED to indicate that the alarm is energized.
- An audible buzzer for alarm events can only be canceled on-site.
Alarm Events:
- Alarm for real-time detection of “abnormal" events.
Communications:
- Relay ports to receive the signal from each relay zone alarm.
Controls:
- One button to cancel the audible alarm, with a reset after 1 hour if the alarm status has not been normalized.
- One button to test the alarm system.
Installation, Operation and Maintenance Equipment Manuals:
- Manuals are protected and is only for arigmed´s equipments. User must send an email with the information requested in the form in the manuals and after-sales service section in this web site click here ,and then complete the requested form.