Medical Gas Master Alarm SERIE 2

*To a quote contact our technical and commercial personnel; Customer information must be valid and true (name, full address, email, telephone, country, zip code, I.D. tax).

**We always request clear specifications to make a formal quote.

Description

Medical Master Panel Alarm for surveillance of Medical Gas Alarm zone groups Model SERIES 2, 7 " full color LCD Display Touch Screen, available only in wall-embedded cabinet, meeting NFPA99.

Cabinet:

  • ABS thermoplastic injection fron made meeting NFPA 286, galvanized steel sheet mounting chassis made.

Zone Alarm Surveillance Capability:

  • 127 medical gas or vacuum sensors connected simultaneously on the SERIES 2 Medical gas Master Panel Alarm.

Graphics:

  • Real-time Pressure and Vacuum levels viewer of each medical gas alarm zone connected to the SERIES 2 Medical Master Panel Alarm.
  • NFPA99 color and Nomenclature option of each medical gas module included on the medical gas alarm zone and connected to the SERIES 2 Medical Master Panel Alarm.
  • ISO color and Nomenclature option of each medical gas module included on the medical gas alarm zone and connected to the SERIES 2 Medical Master Panel Alarm.
  • Flashing Alarms on each Gas Module of the medical gas alarm zone connected to the SERIES 2 Medical Master Panel Alarm.
  • Display of the name of the area where each medical gas alarm zone connected to the SERIES 2 Medical Master Panel Alarm.

Alarm Events:

  • High and low pressure alarm events in real time.

Communications:

  • RJ45 female ports for data input and output.
  • Data dry contact relay port output (1 port).
  • RS485 communication protocol in SERIAL connection to medical gas alarm zone groups with the Ethernet interface (Internet).
  • Connection to INTRANET and EXTRANET (INTERNET) through the ARIGMED ETHERNET INTERFACE with HTML to view the system with remote devices such as PC, TABLET, SMARTPHONE via website.

Features:

  • Editing the Name of the area where the zone alarm will be located.
  • Reports generation to alarm events of the entire system in export files in PDF (Acrobat Reader) and XLS (Excel) formats with a 30 days storage on the system.

Specifications

Requires complementary equipment:
  • Wall recessed box to data and electrical wire block connections.
  • Power input 110-220v 50/60 Htz.
  • CAT6 wire Data NETWORK in SERIAL mode conenction with medical gas alarm zone groups.
To Internet Connection requires:
  • ARIGMED HTML interface
  • Good Qaulity Fixed Internet
  • Arigmed medical gas system manager HTML Hosting (May cause additional costs to user)
Effects on the Equipment operation that must be avoided:
  • Voltage variations in the electrical power supply.
  • Main power supply with emergency power plants.
  • Intermittent Power supply (power lost and regained often in a short time).
Installation recommendations:
  • Check ground connection (to protect from unwanted discharges).
  • Install a system against voltage variations and power backup (Non-Break).
  • Install a system with a surge suppressor (against power surges and discharges).

Brochure

Download:
ficha comercial_ALARMA_MAESTRA_DIGITAL_S2
Download:
General Connection Sample.
Intellectual and industrial property: All rights reserved.
  • All access to this website is subject to the following conditions: The reproduction, permanent storage and dissemination of the contents or any other use that has a public or commercial purpose is forbidden without prior written notice and approval of Grupo Arigmed S. de R.L. de C.V.
  • All documents, images and contents, on this website are from the Intellectual property of Grupo Arigmed S. de R.L. de C.V., any type of copy, plagiarism or similarity in those (documents, images and contents), will be object of legal actions to avoid its use by unauthorized persons, organizations or companies, as well to compensate author´s damage caused.

 

error: Content is protected !!